Insulation
Conventional or reflective – an objective comparison
Good insulation lowers heating costs and makes a home noticeably more comfortable. Which route is right depends on the individual building. Here we first introduce the reflective insulation ISOFOLIE® and then compare conventional insulation materials and reflective systems point by point.
Proper insulation
ISOFOLIE® for roof and wall
Specially manufactured air cushions and highly reflective, aluminium-vapourised foils — for indoor and outdoor use, in roof and wall areas.
What problem does it solve?
In winter a house loses a large part of its heat through the roof and external walls, and in summer heat builds up under the roof. Conventional insulation materials need a lot of space for good values – often 20 centimetres or more. That space is frequently missing: when renovating from the inside, in listed buildings, in converted attics or wherever every centimetre of living space counts.
ISOFOLIE® is a reflective insulation that works with a much lower build-up height and also keeps out the sun’s thermal radiation.
How does the product work?
ISOFOLIE® is used to reduce and prevent solar radiation input or heat radiation losses, as well as transmission heat losses. It can be used in roof and wall areas to reduce cooling and heating loads.
Specially manufactured air cushions and highly reflective aluminium-vapourised foils lend ISOFOLIE® exceptional properties for indoor and outdoor applications. Particularly noteworthy are the thermal conductivity lambda of 0.0198 W/(mK) and the reflection of up to 99 % of solar, cooling and thermal radiation.
ISOFOLIE® makes slim building constructions possible at the same insulation performance. The calculation is carried out according to DIN EN ISO 6946 with the energy demand calculation software from Hottgenroth.
Important for planning: the reflective layer only develops its full effect together with still air layers on one or both sides. That is why it is installed at a distance from the wall or the cladding, and the proof is always provided for the entire build-up – see the sample calculations further down.
Which buildings and applications is it suitable for?
- Renovation from the inside: on the inner side of the external wall when the façade should or must be preserved – in listed buildings, for example.
- Roof and attic: between or below the rafters, where it also reduces overheating in summer.
- New builds and timber construction: as a slim insulation layer in walls and roofs.
- Limited space: wherever a thick insulation layer would cost living space or ceiling height.
It is less suitable where no still air layer can form next to the foil, for example if it were plastered directly or pressed into a cavity.
Use in roof and wall
What are its advantages and limits?
- calculation according to DIN EN ISO 6946
- indoor and outdoor application
- slim building constructions
- easy installation
- reflects thermal radiation back into the room
- keeps out the sun’s thermal radiation
- constant reflection values even after years — the reflective layer is protected from dust
- R-value of the foil from 0.909 to 5.909 (m²K/W)
- can be used as a vapour barrier
- reflects up to 99 % of solar and thermal radiation
- thermal conductivity lambda = 0.0198 W/(mK) according to EN 12667
- no toxic emissions
- no moisture absorption
- low primary energy demand in production
Limits – stated honestly
- The effect depends on the installation: without a still air layer next to the reflective layer, much of it is lost.
- The foil is practically vapour-tight. It belongs on the warm side of the component; when insulating an existing wall from the inside, moisture protection must be checked.
- It stores hardly any heat. It does not delay summer heat the way heavy insulation materials do – it keeps the radiation out.
- As with any interior insulation, connections to windows, ceilings and interior walls must be planned carefully.
- For subsidies and official proof, the calculated U-value of the component counts. Which values are accepted should be clarified in advance with an energy consultant or the funding body.
What investment can roughly be expected?
What insulation costs depends on the area, the existing build-up and the installation situation. The sample house from our system comparison gives a point of reference: for the roof and external walls of a detached house it assumes the following investments. These are guide values for this example, not a quotation – we will gladly calculate for your house.
Which technical certificates and references are available?
The thermal conductivity lambda = 0.0198 W/(mK) was determined on type T4 by the testing institute SGS (test dated 04.09.2015, according to EN 12667). Components are calculated according to DIN EN ISO 6946. The table shows the values of the individual foil thicknesses.
| Type | Thickness (mm) | Lambda (W/mK) | R-value of the foil (m²K/W) | U-value of the foil (W/m²K) | Primary energy in production (kWh/m²) |
|---|---|---|---|---|---|
| ISOFOLIE T1.0 | 18 | 0.0198 | 0.909 | 1.100 | 1 |
| ISOFOLIE T2.5 | 36 | 0.0198 | 1.818 | 0.550 | 1 |
| ISOFOLIE T3.0 | 54 | 0.0198 | 2.727 | 0.366 | 2 |
| ISOFOLIE T3.5 | 63 | 0.0198 | 3.181 | 0.314 | 2 |
| ISOFOLIE T4.0 | 81 | 0.0198 | 4.090 | 0.244 | 3 |
| ISOFOLIE T4.5 | 99 | 0.0198 | 5.000 | 0.200 | 4 |
| ISOFOLIE T5.0 | 117 | 0.0198 | 5.909 | 0.169 | 5 |
Manufacturer’s data. R- and U-values apply to the foil alone (R = thickness ÷ lambda). The U-value of a component only results from all layers, air layers and surface resistances – two complete sample calculations (concrete wall and listed brick building) can be found in the documents.
Pictures for illustration during installation
Referenzen ISOFOLIE®
In our own house in San Fulgencio we insulated the external walls on the inside with ISOFOLIE® behind a drywall lining, combined with carbon underfloor heating. According to the energy certificate, the house moved from class G to class B. See the case study Spain under References
How do you get an individual quotation?
Send us a few photos, the approximate dimensions of the roof and walls and – if available – plans or the energy certificate. We check the existing build-up, calculate the U-value of the possible solution and make you an offer.
Insulation reconsidered
Which solution suits your building?
Mineral wool, wood fibre, polystyrene or a reflective system such as ISOFOLIE®: every solution has its strengths. Which one suits your house depends on the existing build-up, the available space, the moisture situation and the budget.
What really matters
What counts is not the individual material but the entire component. How much heat a wall or roof loses is described by the thermal resistance (R-value) of all layers together – or its reciprocal, the U-value. Thermal bridges at connections, moisture behaviour, protection from summer heat, cost and the question of how a solution can be installed in the specific building also matter.
The following overview compares both approaches according to these criteria.
Conventional insulation and reflective systems compared
| Criterion | Conventional insulation (e.g. mineral wool, wood fibre, EPS/XPS) | Reflective systems (e.g. ISOFOLIE®) |
|---|---|---|
| Principle | Still air in fibres or pores slows down heat conduction. | Reflective surfaces with low emissivity reduce heat transfer by radiation – together with still air layers. |
| Thermal resistance of the entire component | Increases with thickness (R = thickness ÷ lambda). Proven, standardised values. | Depends strongly on the adjacent still air layers. Proof also via the U-value of the entire build-up according to DIN EN ISO 6946. |
| Thermal bridges | Gap-free installation required; connections to windows, ceilings and shutter boxes remain weak points. | Likewise: seal joints tightly, keep air layers continuous. With interior insulation, plan for adjoining ceilings and walls. |
| Moisture behaviour | Depending on the material vapour-open (mineral wool, with vapour retarder), capillary-active (wood fibre) or vapour-retardant (polystyrene). | Aluminium-coated foils are practically vapour-tight and act as a vapour barrier. They belong on the warm side; check moisture protection. |
| Summer heat protection | Heavy materials such as wood fibre delay heat through thermal mass; light materials hardly do. | Keeps out thermal radiation, particularly effective under the roof. Stores hardly any heat itself. |
| Build-up height | For a U-value of around 0.2 W/(m²K), roughly 15 to 25 cm depending on the material. | Foil 18 to 117 mm plus air layers. Sample calculation concrete wall: U-value 0.14 to 0.22 W/(m²K) with 13 to 19 cm build-up on the inside. |
| Cost (sample house system comparison, roof and wall) | approx. €105,000 | approx. €75,000 |
| Embodied energy (primary energy per m²) | roughly 10 to 350 kWh/m² at 20 cm, depending on the material | 1 to 5 kWh/m² depending on foil thickness |
| Typical installation | External façade (ETICS), roof, basement ceiling; interior insulation with moisture assessment. | Inside of the external wall, roof and attic, listed buildings, components with little space. |
Sources: manufacturer’s sample calculations for U-value and primary energy demand (primary energy of conventional materials based on IWU data), costs from the system comparison on the Heating page. Guide values for the respective examples – for a specific building the overview does not replace a calculation.
How reflective insulation works – and what it depends on
Heat travels through a component in three ways: by conduction, by air movement and by radiation. In an air layer, radiation accounts for a large share. A shiny aluminium surface emits hardly any heat itself and reflects incoming thermal radiation – this significantly reduces heat transfer across the air layer.
The phrase “reflection instead of storage” therefore falls short. Reflection only works if a still air layer is in contact with the foil. If the foil is plastered directly or the air layer is ventilated, much of the effect is lost. The standard DIN EN ISO 6946 takes this into account via the emissivity of the surfaces: in the manufacturer’s sample calculation, each still air layer next to the foil contributes 0.57 m²K/W to the thermal resistance.
That is why the same applies to reflective and conventional insulation: what is compared is the U-value of the entire build-up, not the figure for a single material.
Strengths and limits of reflective systems
Strengths
- low build-up height with good U-values
- effective protection against summer heat under the roof
- suitable for interior insulation when the façade is to be preserved
- little embodied energy, no moisture absorption
Limits
- effective only with still air layers – careful installation is essential
- vapour-tight: position in the component and moisture protection must be right
- hardly any thermal mass, no time delay of heat
- agree on values in advance with an energy consultant or funding body
Which solution suits your building?
Often the best answer is a combination. We look at your house, calculate the possible build-ups and recommend what suits the building, the space and the budget.
Arrange an introductory call
We look at your house, work through the comparison and tell you which building blocks pay off in your case — and which do not.